CommScope Type N Male for CNT-240 braided cable
$19.84
- Brand
- CommScope
- SKU:
- 240BPNM-C-CR
- Weight:
- 0.06 LBS
- Shipping:
- Calculated at Checkout
CommScope Type N Male for CNT-240 braided cable
| General Specifications | |
| Interface | N Male |
| Body Style | Straight |
| Brand | CNT® |
| Electrical Specifications | |
| Operating Frequency Band | 0 – 6000 MHz |
| Cable Impedance | 50 ohm |
| Connector Impedance | 50 ohm |
| RF Operating Voltage, maximum (vrms) | 529.00 V |
| dc Test Voltage | 1500 V |
| Outer Contact Resistance, maximum | 0.25 mOhm |
| Inner Contact Resistance, maximum | 1.00 mOhm |
| Insulation Resistance, minimum | 5000 MOhm |
| Average Power | 260.0 W @ 900 MHz |
| Peak Power, maximum | 5.60 kW |
| Insertion Loss, typical | 0.05 dB |
| Mechanical Specifications | |
| Outer Contact Plating | Trimetal |
| Inner Contact Plating | Silver |
| Outer Contact Attachment Method | Crimp |
| Inner Contact Attachment Method | Captivated |
| Interface Durability | 500 cycles |
| Interface Durability Method | IEC 61169-16:9.5 |
| Connector Retention Tensile Force | 134 N | 30 lbf |
| Connector Retention Torque | 0.23 N-m | 0.17 ft lb |
| Coupling Nut Proof Torque | 1.70 N-m | 1.25 ft lb |
| Coupling Nut Proof Torque Method | IEC 61169-16:9.3.6 |
| Coupling Nut Retention Force | 450.00 N | 101.16 lbf |
| Coupling Nut Retention Force Method | IEC 61169-16:9.3.11 |
| Dimensions | |
| Nominal Size | 0.240 in |
| Diameter | 22.35 mm | 0.88 in |
| Length | 44.81 mm | 1.76 in |
| Weight | 39.12 g | 0.09 lb |
| Width | 22.35 mm | 0.88 in |
| Environmental Specifications | |
| Operating Temperature | -40 °C to +85 °C (-40 °F to +185 °F) |
| Storage Temperature | -65 °C to +125 °C (-85 °F to +257 °F) |
| Water Jetting Test Mating | Mated |
| Water Jetting Test Method | IEC 60529:2001, IP65 |
| Mechanical Shock Test Method | IEC 60068-2-27 |
| Climatic Sequence Test Method | IEC 60068-1 |
| Damp Heat Steady State Test Method | IEC 60068-2-3 |
| Thermal Shock Test Method | IEC 60068-2-14 |
| Vibration Test Method | IEC 60068-2-6 |
| Corrosion Test Method | IEC 60068-2-11 |
| Standard Conditions | |
| Attenuation, Ambient Temperature | 20 °C | 68 °F |
| Average Power, Ambient Temperature | 40 °C | 104 °F |
| Average Power, Inner Conductor Temperature | 100 °C | 212 °F |
Return Loss/VSWR
| Frequency Band | VSWR | Return Loss (dB) |
| 0–3000 MHz | 1.08 | 28.00 |
| 3000–6000 MHz | 1.22 | 20.00 |
Regulatory Compliance/Certifications
| Agency | Classification |
| RoHS 2011/65/EU | Compliant by Exemption |
| China RoHS SJ/T 11364-2006 | Above Maximum Concentration Value (MCV) |
| ISO 9001:2008 | Designed, manufactured and/or distributed under this quality management system |