Type N Male with gas barrier for 7/8 in HJ5-50 air dielectric cable
General Specifications | |
Interface | N Male |
Body Style | Straight |
Brand | HELIAX® |
Gas Barrier | Yes |
Mounting Angle | Straight |
Electrical Specifications | |
Connector Impedance | 50 ohm |
Operating Frequency Band | 0 – 5200 MHz |
Cable Impedance | 50 ohm |
RF Operating Voltage, maximum (vrms) | 707.00 V |
dc Test Voltage | 2 kV |
Insulation Resistance, minimum | 5000 MOhm |
Average Power | 0.6 kW @ 900 MHz |
Peak Power, maximum | 10.00 kW |
Insertion Loss, typical | 0.05 dB |
Mechanical Specifications | |
Outer Contact Attachment Method | Tab-flare |
Inner Contact Attachment Method | Self-tapping |
Outer Contact Plating | Silver |
Inner Contact Plating | Gold |
Interface Durability | 500 cycles |
Interface Durability Method | MIL-C-39012, Section 4.6.12 |
Dimensions | |
Nominal Size | 7/8 in |
Diameter | 34.67 mm | 1.37 in |
Length | 83.24 mm | 3.28 in |
Weight | 0.33 kg | 0.72 lb |
Environmental Specifications | |
Operating Temperature | -40 °C to +150 °C (-40 °F to +302 °F) |
Storage Temperature | -70 °C to +100 °C (-94 °F to +212 °F) |
Moisture Resistance Test Method | MIL-STD-202, Method 106 |
Mechanical Shock Test Method | MIL-STD-202, Method 213, Test Condition I |
Thermal Shock Test Method | MIL-STD-202, Method 107, Test Condition A-1, Low Temperature -55 °C |
Vibration Test Method | MIL-STD-202, Method 204, Test Condition B |
Corrosion Test Method | MIL-STD-202, Method 101, Test Condition B |
Return Loss/VSWR
Frequency Band | VSWR | Return Loss (dB) |
0–1000 MHz | 1.02 | 40.00 |
1000–2200 MHz | 1.03 | 38.00 |
2200–4000 MHz | 1.12 | 25.00 |
4000–7000 MHz | 1.22 | 20.00 |
7000–10000 MHz | 1.43 | 15.00 |
Regulatory Compliance/Certifications
Agency | Classification |
ISO 9001:2008 | Designed, manufactured and/or distributed under this quality management system |