| General Specifications | |
| Interface | N Female |
| Body Style | Straight |
| Brand | HELIAX® |
| Gas Barrier | Yes |
| Mounting Angle | Straight |
| Electrical Specifications | |
| Connector Impedance | 50 ohm |
| Operating Frequency Band | 0 – 5200 MHz |
| Cable Impedance | 50 ohm |
| RF Operating Voltage, maximum (vrms) | 707.00 V |
| dc Test Voltage | 2 kV |
| Insulation Resistance, minimum | 5000 MOhm |
| Average Power | 0.6 kW @ 900 MHz |
| Peak Power, maximum | 10.00 kW |
| Insertion Loss, typical | 0.05 dB |
| Mechanical Specifications | |
| Outer Contact Attachment Method | Tab-flare |
| Inner Contact Attachment Method | Self-tapping |
| Outer Contact Plating | Silver |
| Inner Contact Plating | Gold |
| Interface Durability | 500 cycles |
| Interface Durability Method | MIL-C-39012, Section 4.6.12 |
| Dimensions | |
| Nominal Size | 7/8 in |
| Diameter | 34.67 mm | 1.37 in |
| Length | 81.25 mm | 3.20 in |
| Weight | 0.33 kg | 0.72 lb |
| Environmental Specifications | |
| Operating Temperature | -40 °C to +150 °C (-40 °F to +302 °F) |
| Storage Temperature | -70 °C to +100 °C (-94 °F to +212 °F) |
| Moisture Resistance Test Method | MIL-STD-202, Method 106 |
| Mechanical Shock Test Method | MIL-STD-202, Method 213, Test Condition I |
| Thermal Shock Test Method | MIL-STD-202, Method 107, Test Condition A-1, Low Temperature -55 °C |
| Vibration Test Method | MIL-STD-202, Method 204, Test Condition B |
| Corrosion Test Method | MIL-STD-202, Method 101, Test Condition B |
Return Loss/VSWR
| Frequency Band | VSWR | Return Loss (dB) |
| 45–1080 MHz | 1.02 | 41.00 |
| 1080–1590 MHz | 1.05 | 33.00 |
| 1590–2110 MHz | 1.07 | 29.00 |
| 2110–4680 MHz | 1.08 | 28.00 |
| 4680–5200 MHz | 1.15 | 23.00 |
Regulatory Compliance/Certifications
| Agency | Classification |
| RoHS 2011/65/EU | Compliant by Exemption |
| China RoHS SJ/T 11364-2006 | Above Maximum Concentration Value (MCV) |
| ISO 9001:2008 | Designed, manufactured and/or distributed under this quality management system |